{"product_id":"ieej-ld11072","title":"次世代体内－体外間情報通信システムの電極検討","description":"\u003cp\u003e\u003cstrong\u003eカテゴリ: \u003c\/strong\u003e研究会(論文単位)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e論文No: \u003c\/strong\u003eLD11072\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eグループ名: \u003c\/strong\u003e【D】産業応用部門 リニアドライブ研究会\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e発行日: \u003c\/strong\u003e2011\/11\/24\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eタイトル(英語): \u003c\/strong\u003eExamination of electrodes for a new transcutaneous information transmission using intra-body communication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名: \u003c\/strong\u003e加藤 良都(東海大学),岡本 英治(東海大学),情野 和幸(東海大学),菊地 咲子(東海大学),三田村 好矩(東海大学)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名(英語): \u003c\/strong\u003eYoshikuni Kato(Graduate shool of Tokai University),Eiji Okamoto(Graduate shool of Tokai University),Kazuyuki Seino(Tokai University),Sakiko Kikuchi(Tokai University),Yoshinori Mitamura(Graduate shool of Tokai University)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eキーワード: \u003c\/strong\u003e人工心臓|体内通信|経皮的情報伝送システム|人工臓器|artificial heart|intra-body|communication\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(日本語): \u003c\/strong\u003e本研究では臨床に用いる次世代の通信システムの開発を行っている．体内－体外間通信において送受信効率を考える必要があるため，送受信電極として複数の金属を用い利得の検証を行った．電極にはAg\/AgCl電極，チタン板，ステンレス板，アルミ板を用い比較した．結果は体外側には利得が高く安定しているステンレスを採用することとした．今後は，体内側電極と生体との接触の安定化を含めて体内側電極の検討を行う予定である．\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(英語): \u003c\/strong\u003eResistance between an electrode and tissue is one of important parameters to determine data transmission performance of a transcutaneous data transmission using intra-body communication technology. We measured electrode-tissue resistance in four kinds of electrodes (stainless steel, titanium alloy, Ag-AgCl electrode, Ag-AgCl paste electrode). Measurement results shows that the stainless steel electrode has the lower resistance and superior transmission characteristics rather than other electrodes. From this result, the stainless steel electrode is a suitable electrode for an external unit of the transcutaneous data transmission using intra-body communication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e原稿種別: \u003c\/strong\u003e日本語\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePDFファイルサイズ: \u003c\/strong\u003e4,559 Kバイト\u003c\/p\u003e","brand":"IEEJ-PDF","offers":[{"title":"PDFダウンロード（一般価格330円\/会員価格220円） \/ A4 \/ 4","offer_id":46393891061999,"sku":"IEEJ-LD11072-PDF","price":330.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9512\/2159\/files\/IEEJ-PDF_82c24a3f-c54f-4525-82e0-1da3421087bc.png?v=1744712612","url":"https:\/\/ieej.bookpark.ne.jp\/products\/ieej-ld11072","provider":"電気学会 電子図書館","version":"1.0","type":"link"}