{"product_id":"ieej-pe15167","title":"Minimization of voltage deviation based on expanded flow algorithm for online reconfiguration of distribution system with interconnection of distributed generators","description":"\u003cp\u003e\u003cstrong\u003eカテゴリ: \u003c\/strong\u003e研究会(論文単位)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e論文No: \u003c\/strong\u003ePE15167\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eグループ名: \u003c\/strong\u003e【B】電力・エネルギー部門 電力技術研究会\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e発行日: \u003c\/strong\u003e2015\/09\/18\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eタイトル(英語): \u003c\/strong\u003eMinimization of voltage deviation based on expanded flow algorithm for online reconfiguration of distribution system with interconnection of distributed generators\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名: \u003c\/strong\u003eファン ジェン(北海道大学),原 亮一(北海道大学),北 裕幸(北海道大学)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名(英語): \u003c\/strong\u003eZheng Huang(Hokkaido University),Ryoichi Hara(Hokkaido University),Hiroyuki Kita(Hokkaido University)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eキーワード: \u003c\/strong\u003eexpanded flow algorithm|minimization of voltage deviations|distribution system reconfiguration|power distribution planning|distributed generators\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(日本語): \u003c\/strong\u003eInterconnection of the distributed generators (DG) to the power system causes the efficiency degradation of distribution system management. Minimization of voltage deviation on network reconfiguration is one of the important solutions of this problem. The intelligent flow algorithm (IFA) was proposed in the past researches to solve reconfiguration issues. In this paper, the expanded flow algorithm (EFA) is proposed based on the IFA to cope with the DG installations to the distribution systems. The EFA method mainly utilizes the configuration with lower degree of supplying imbalance to search the optimal solution efficiently. The proposed EFA method is validated by simulations with 33-bus and 43-bus test distribution systems. Simulation results show that the EFA is accurate, fast and stable to solve online reconfiguration in the distribution system with DG installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(英語): \u003c\/strong\u003eInterconnection of the distributed generators (DG) to the power system causes the efficiency degradation of distribution system management. Minimization of voltage deviation on network reconfiguration is one of the important solutions of this problem. The intelligent flow algorithm (IFA) was proposed in the past researches to solve reconfiguration issues. In this paper, the expanded flow algorithm (EFA) is proposed based on the IFA to cope with the DG installations to the distribution systems. The EFA method mainly utilizes the configuration with lower degree of supplying imbalance to search the optimal solution efficiently. The proposed EFA method is validated by simulations with 33-bus and 43-bus test distribution systems. Simulation results show that the EFA is accurate, fast and stable to solve online reconfiguration in the distribution system with DG installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e原稿種別: \u003c\/strong\u003e英語\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePDFファイルサイズ: \u003c\/strong\u003e1,454 Kバイト\u003c\/p\u003e","brand":"IEEJ-PDF","offers":[{"title":"PDFダウンロード（一般価格330円\/会員価格220円） \/ A4 \/ 6","offer_id":46359733928175,"sku":"IEEJ-PE15167-PDF","price":330.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9512\/2159\/files\/IEEJ-PDF_6b6cb11d-ab16-4a80-8ece-e56a4871033c.png?v=1743494007","url":"https:\/\/ieej.bookpark.ne.jp\/products\/ieej-pe15167","provider":"電気学会 電子図書館","version":"1.0","type":"link"}