{"product_id":"ieej-ppr20014","title":"IEDを用いた電圧低下揚水遮断リレーシステム（UVPS）の開発・適用","description":"\u003cp\u003e\u003cstrong\u003eカテゴリ: \u003c\/strong\u003e研究会(論文単位)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e論文No: \u003c\/strong\u003ePPR20014\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eグループ名: \u003c\/strong\u003e【B】電力・エネルギー部門 保護リレ－システム研究会\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e発行日: \u003c\/strong\u003e2020\/11\/18\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eタイトル(英語): \u003c\/strong\u003eDevelopment and Application of Under Voltage Pumped storage hydro Shedding system using IED\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名: \u003c\/strong\u003e鈴木 淑子(東京電力パワーグリッド),市川 義治(東京電力パワーグリッド),小熊 順一(東京電設サービス),竹井 勝則(東京電設サービス),伊藤 大道(東京電設サービス)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名(英語): \u003c\/strong\u003eToshiko Suzuki(Tokyo Electric Power Copany Power Grid, Inc.),Yoshiharu Ichikawa(Tokyo Electric Power Copany Power Grid, Inc.),Junichi Oguma(Tokyo Densetsu Service Co.,Ltd.),Katsunori Takei(Tokyo Densetsu Service Co.,Ltd.),Hiromichi Ito(Tokyo Densetsu Service Co.,Ltd.)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eキーワード: \u003c\/strong\u003e電圧低下リレー|揚水遮断|直流連系|直流高圧送電|ＵＶＰＳ|ＩＥＤ|Under Voltage Relay |Pumped storage hydro shedding|DC link|HVDC|UVPS|GE\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(日本語): \u003c\/strong\u003e東日本50Hz地域と西日本60Hz地域には現在合計で1200MWの周波数変換設備があるが，2020年9月に追加で900MWの直流高圧送電線が運用開始する予定となっている。_x000D_\nしかしながら，系統末端に同連系線を接続すると，既設の周波数変換設備の運転状態等によって，東電ＰＧ系統側では本系統と連系している500kV送電線１回線の事故で，系統の電圧を維持できなくなることがわっかっている。そこで，500kV送電線１回線事故を検出し，電圧低下条件が成立した場合に周辺の負荷を遮断するリレーシステムを開発したので報告する\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(英語): \u003c\/strong\u003eThis report describes about the new Under Voltage Pumped storage hydro Shedding relay system (hereinafter called “UVPS”) constructed using GE IED._x000D_\n In Japan, there are two different frequency systems, 50Hz and 60Hz. They are connected each other through 1200MW of back to back frequency conversion facilities. And additional 900MW interconnecting High Voltage DC transmission lines (hereinafter called “HVDC”) are about to be in operation. _x000D_\n However, the new HVDC could cause the problem in voltage because it is connected to the edge of TEPCO’s power grid. For example, the loss of single 500kV transmission line could cause voltage sag problem in the part of bulk transmission system, which violates the TEPCO’s criteria. The drastic measure is constructing additional transmission lines. But which costs much and takes too long period. Therefore, TEPCO has chosen the solution of UVPS that measures the power flows before the fault, detects loss of single transmission line due to the fault, detects the voltage sag condition, and sheds several pumped storage hydro machines._x000D_\n TDS developed the UVPS using IED, and TEPCO resulted it can make the new HVDC meet criteria with extremely less cost and short period.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e原稿種別: \u003c\/strong\u003e日本語\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePDFファイルサイズ: \u003c\/strong\u003e1,121 Kバイト\u003c\/p\u003e","brand":"IEEJ-PDF","offers":[{"title":"PDFダウンロード（一般価格330円\/会員価格220円） \/ A4 \/ 6","offer_id":46359985815791,"sku":"IEEJ-PPR20014-PDF","price":330.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9512\/2159\/files\/IEEJ-PDF_fd5498eb-c32b-4682-a62a-3e1d144c3159.png?v=1743503061","url":"https:\/\/ieej.bookpark.ne.jp\/products\/ieej-ppr20014","provider":"電気学会 電子図書館","version":"1.0","type":"link"}