{"product_id":"ieej-pse12007","title":"大量の風力発電を含む電力系統における電圧制御手法の研究","description":"\u003cp\u003e\u003cstrong\u003eカテゴリ: \u003c\/strong\u003e研究会(論文単位)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e論文No: \u003c\/strong\u003ePSE12007\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eグループ名: \u003c\/strong\u003e【B】電力・エネルギー部門 電力系統技術研究会\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e発行日: \u003c\/strong\u003e2012\/01\/27\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eタイトル(英語): \u003c\/strong\u003eA Study on Voltage Control in Power System  with High Penetration of Wind Farms\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名: \u003c\/strong\u003eTRAN NGUYEN(横浜国立大学),辻 隆男(横浜国立大学),大山 力(横浜国立大学)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名(英語): \u003c\/strong\u003eTRAN NGUYEN(Yokohama National University),TSUJI TAKAO(Yokohama National University),OYAMA TSUTOMU(Yokohama National University)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eキーワード: \u003c\/strong\u003eコンデンサ|電圧安定|風力発電|Ｎ－１基準|static condenser|voltage stability|Wind Farm|N-1 Criterion\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(日本語): \u003c\/strong\u003eThe high penetration of wind farms in the transmission system causes difficulty for system operation such as voltage fluctuation, optimal system operation. In this study, the voltage fluctuation caused by output variation of wind farms (WF) is considered. In the conventional system, static condensers (SCs) play the role to keep the system voltage in the proper range with load change. Then, generation variation of WFs causes nodal to pass over the upper limit. Thus, the injected capacity of SCs is necessary to control for preventing overvoltage risk passing over the predefined value. The control capacity of SC is determined by loop calculation basing on sensitivity of SCs\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(英語): \u003c\/strong\u003eThe high penetration of wind farms in the transmission system causes difficulty for system operation such as voltage fluctuation, optimal system operation. In this study, the voltage fluctuation caused by output variation of wind farms (WF) is considered. In the conventional system, static condensers (SCs) play the role to keep the system voltage in the proper range with load change. Then, generation variation of WFs causes nodal to pass over the upper limit. Thus, the injected capacity of SCs is necessary to control for preventing overvoltage risk passing over the predefined value. The control capacity of SC is determined by loop calculation basing on sensitivity of SCs\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e原稿種別: \u003c\/strong\u003e日本語\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePDFファイルサイズ: \u003c\/strong\u003e985 Kバイト\u003c\/p\u003e","brand":"IEEJ-PDF","offers":[{"title":"PDFダウンロード（一般価格330円\/会員価格220円） \/ A4 \/ 5","offer_id":46359606460655,"sku":"IEEJ-PSE12007-PDF","price":330.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9512\/2159\/files\/IEEJ-PDF_c83915c4-bd06-4b79-ac5f-6daef2167ccf.png?v=1743488799","url":"https:\/\/ieej.bookpark.ne.jp\/products\/ieej-pse12007","provider":"電気学会 電子図書館","version":"1.0","type":"link"}