{"product_id":"ieej-sp10030","title":"英文論文","description":"\u003cp\u003e\u003cstrong\u003eカテゴリ: \u003c\/strong\u003e研究会(論文単位)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e論文No: \u003c\/strong\u003eSP10030\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eグループ名: \u003c\/strong\u003e【B】電力・エネルギー部門 開閉保護研究会\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e発行日: \u003c\/strong\u003e2010\/11\/12\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eタイトル(英語): \u003c\/strong\u003eResearch activities related to T\u0026amp;D equipment and systems \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名: \u003c\/strong\u003e池田 久利(東京大学),中島 達人(東京大学),熊田 亜紀子(東京大学),日高 邦彦(東京大学)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名(英語): \u003c\/strong\u003eIKEDA HISATOSHI(The University of Tokyo),NAKAJIMA TATSUTO(The University of Tokyo),KUMADA AKIKO(The University of Tokyo),HIDAKA KUNIHIKO(The University of Tokyo)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eキーワード: \u003c\/strong\u003e送電配電機器システム|テラヘルツ波|水トリー|マイクロレンズアレイ|電子密度|Ｖ－ｔ特性|transmission and distribution equipment and systems|tera Hz |water tree |micro-lens array |electron density |v-t characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(日本語): \u003c\/strong\u003e東京大学の先端電力エネルギー・環境技術教育研究センターには2008年よりパワーフロンティア寄附講座が開講している。ここでは送電配電の機器やシステムに関する研究が進められている。テラHzを用いた電力用PEケーブルの水トリーを非破壊的に観測する技術が研究されている。マイクロレンズアレイを用いてシャックハルトマン法でアークプラズマ中の電子密度計測が行われている。また、真空バルブのV-t特性や変圧器の解析モデルの研究が進められている。これらの研究を紹介する。\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(英語): \u003c\/strong\u003eThe granted laboratory, ‘Power Frontier’, has been operating in the Center for Advanced Power \u0026amp; Environmental Technology in the University of Tokyo since 2008. Various research works were started in the field of transmission and distribution equipment and systems. The tera Hz technology was introduced to viewing non-disruptively the water tree in a polyethylene power cable. The micro-lens array was introduced to measuring an electron density in an arc plasma by using the Shack Haltman method. The v-t characteristics of a vacuum interrupter was measured. The transformer model was derived for an accurate computation of the transient recovery voltage at interrupting the transformer limited fault condition. These  works will be introduced.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e原稿種別: \u003c\/strong\u003e日本語\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePDFファイルサイズ: \u003c\/strong\u003e855 Kバイト\u003c\/p\u003e","brand":"IEEJ-PDF","offers":[{"title":"PDFダウンロード（一般価格330円\/会員価格220円） \/ A4 \/ 6","offer_id":46376717877487,"sku":"IEEJ-SP10030-PDF","price":330.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9512\/2159\/files\/IEEJ-PDF_88b84b35-2655-4a78-92d3-3e94d4a0652c.png?v=1744113135","url":"https:\/\/ieej.bookpark.ne.jp\/products\/ieej-sp10030","provider":"電気学会 電子図書館","version":"1.0","type":"link"}