{"product_id":"ieej-sp18055","title":"Basic Research on Partial Discharge Detection for Power Cables by Sheath Current Measurement","description":"\u003cp\u003e\u003cstrong\u003eカテゴリ: \u003c\/strong\u003e研究会(論文単位)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e論文No: \u003c\/strong\u003eSP18055\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eグループ名: \u003c\/strong\u003e【B】電力・エネルギー部門 開閉保護研究会\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e発行日: \u003c\/strong\u003e2018\/11\/03\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eタイトル(英語): \u003c\/strong\u003eBasic Research on Partial Discharge Detection for Power Cables by Sheath Current Measurement\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名: \u003c\/strong\u003eOgbugo Michael Arinze(Shibaura Institute of Technology),Matsubara Hiroji(Shibaura Institute of Technology),Matsumoto Satoshi(Shibaura Institute of Technology)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名(英語): \u003c\/strong\u003eMichael Arinze Ogbugo(Shibaura Institute of Technology),Hiroji Matsubara(Shibaura Institute of Technology),Satoshi Matsumoto(Shibaura Institute of Technology)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eキーワード: \u003c\/strong\u003eCable Insulation|High Voltage|Partial Discharge Detection|Power Cable|Pulse Injection|Sheath Current Measurement|Cable Insulation|High Voltage|Partial Discharge Detection|Power Cable|Pulse Injection|Sheath Current Measurement\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(日本語): \u003c\/strong\u003eDeterioration in the insulation performance of high voltage XLPE cables is believed to be attributed to the deterioration caused by partial discharges. Detecting partial discharge is an effective way to evaluate the condition of high-voltage electrical equipment insulation. In this study, experimental work was done by cutting a cable to measure the voltage and current of both the core and sheath. When the sheath current and the sheath potential was measured directly, the measured value which is large, is very important for partial discharge detection, and also has the advantage of having no need to develop a new measuring instrument\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(英語): \u003c\/strong\u003eDeterioration in the insulation performance of high voltage XLPE cables is believed to be attributed to the deterioration caused by partial discharges. Detecting partial discharge is an effective way to evaluate the condition of high-voltage electrical equipment insulation. In this study, experimental work was done by cutting a cable to measure the voltage and current of both the core and sheath. When the sheath current and the sheath potential was measured directly, the measured value which is large, is very important for partial discharge detection, and also has the advantage of having no need to develop a new measuring instrument\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e原稿種別: \u003c\/strong\u003e英語\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePDFファイルサイズ: \u003c\/strong\u003e1,653 Kバイト\u003c\/p\u003e","brand":"IEEJ-PDF","offers":[{"title":"PDFダウンロード（一般価格330円\/会員価格220円） \/ A4 \/ 5","offer_id":46390780494063,"sku":"IEEJ-SP18055-PDF","price":330.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9512\/2159\/files\/IEEJ-PDF_2c7a1042-2826-4beb-9085-e41c8899f001.png?v=1744603288","url":"https:\/\/ieej.bookpark.ne.jp\/products\/ieej-sp18055","provider":"電気学会 電子図書館","version":"1.0","type":"link"}