{"product_id":"ieej-spc14154hca14062vt14049","title":"三相インターリーブ方式DC-DCコンバータのワンシャント電流検出による全デューティ比をカバーするインダクタ電流制御","description":"\u003cp\u003e\u003cstrong\u003eカテゴリ: \u003c\/strong\u003e研究会(論文単位)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e論文No: \u003c\/strong\u003eSPC14154,HCA14062,VT14049\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eグループ名: \u003c\/strong\u003e【D】産業応用部門 半導体電力変換\/【D】産業応用部門 家電・民生\/【D】産業応用部門 自動車合同研究会\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e発行日: \u003c\/strong\u003e2014\/12\/18\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eタイトル(英語): \u003c\/strong\u003eInductor Current Control of Three-Phase Interleaved DC-DC Converter for All Range of Duty Ratio by High-side DC-Link Current Detection using a Shunt Resistor\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名: \u003c\/strong\u003e中山 暁斗(東京理科大学),星 伸一(東京理科大学)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e著者名(英語): \u003c\/strong\u003eAkito Nakayama(Tokyo University of Science),Nobukazu Hoshi(Tokyo University of Science)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eキーワード: \u003c\/strong\u003e三相インターリーブ方式ＤＣ－ＤＣコンバータ|ワンシャント電流検出|three-phase interleaved DC-DC converter|current detection using a shunt resister\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(日本語): \u003c\/strong\u003e三相インターリーブ方式DC-DCコンバータでは各相のインダクタの個体差により生じる相間のインダクタ電流の不均衡を解消するために，従来，各相のインダクタ電流を検出して制御を行ってきた。そのため電流を検出するセンサが三つ必要となり，コスト面や回路の大きさに影響してきた。_x000D_\nしかし本研究では電流を検出するためのシャント抵抗によるセンサを高圧側DCリンク部に一つだけ用いることで各相のインダクタ電流を推定し，制御する。_x000D_\n以前に報告した方式では，各相下側スイッチのデューティ比が全て0.33以上の場合に限られていたが，本稿では各相下側スイッチのデューティ比が全て0.33以下の場合にも適用可能な制御法を提案し，その有効性を示す。また，各相下側スイッチのデューティ比が0.33以上と以下で混在する場合におけるインダクタ電流の推定方法も合わせて提案する。_x000D_\n\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e要約(英語): \u003c\/strong\u003eGenerally, the inductor currents of three-phase interleaved DC-DC converter are controlled by detecting each phase inductor current in order to resolve the problem that the individual difference of each inductor causes unbalance of each inductor current. In this scheme, three current sensors are required, causing increases of the cost, the volume, and the weight._x000D_\nThis paper proposes an inductor current control of three-phase interleaved DC-DC converter by high-side DC-link current detection using a shunt resistor._x000D_\nIn previous-reported control method, the duty ratio of lower arm of each phase was limited more than one third._x000D_\nThus, this paper proposes a novel control method which can control the inductor current even if the duty ratio is less than one third._x000D_\nAdditionally, this paper explains a control method under the case where the duty ratio is mixed with both more than one third and less than one third._x000D_\nMoreover, the effectiveness of the proposed control method was verified by simulations and experiments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e原稿種別: \u003c\/strong\u003e日本語\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePDFファイルサイズ: \u003c\/strong\u003e1,428 Kバイト\u003c\/p\u003e","brand":"IEEJ-PDF","offers":[{"title":"PDFダウンロード（一般価格330円\/会員価格220円） \/ A4 \/ 6","offer_id":46393347408111,"sku":"IEEJ-SPC14154HCA14062VT14049-PDF","price":330.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9512\/2159\/files\/IEEJ-PDF_acedaded-e2ef-4451-8afe-80046ba5bf04.png?v=1744688861","url":"https:\/\/ieej.bookpark.ne.jp\/products\/ieej-spc14154hca14062vt14049","provider":"電気学会 電子図書館","version":"1.0","type":"link"}