商品情報にスキップ
1 2

Evaluation of Central Arterial Blood Pressure on Urban, Rural, and Semi-urban Population in India Using ARTSENS

Evaluation of Central Arterial Blood Pressure on Urban, Rural, and Semi-urban Population in India Using ARTSENS

通常価格 ¥660 JPY
通常価格 セール価格 ¥660 JPY
セール 売り切れ
税込

カテゴリ: 研究会(論文単位)

論文No: CMN21026

グループ名: 【C】電子・情報・システム部門 通信研究会

発行日: 2021/03/23

タイトル(英語): Evaluation of Central Arterial Blood Pressure on Urban, Rural, and Semi-urban Population in India Using ARTSENS

著者名: Nabeel P M(IIT Madras),Kiran V Raj(IIT Madras),Joseph Jayaraj(IIT Madras),Sivaprakasam Mohanasankar(IIT Madras)

著者名(英語): P M Nabeel(IIT Madras),Raj Kiran V(IIT Madras),Jayaraj Joseph(IIT Madras),Mohanasankar Sivaprakasam(IIT Madras)

キーワード: ARTSENS|carotid|blood pressure|carotid pressure|ultrasound|central BP|ARTSENS|carotid|blood pressure|carotid pressure|ultrasound|central BP

要約(日本語): We present a method for evaluating blood pressure from the carotid artery using an image-free ultrasound device ? ARTSENS. It was validated on 390 subjects (45±10 years) from the urban, rural, and semi-urban regions in India. In compliance with theory, the carotid pulse pressure (25.3±9.4 mmHg) and systolic pressure (99.4±16.5 mmHg) were significantly lower (p<0.0001) than those of the brachial artery (39.7±14.2 mmHg, 113.7±20.0 mmHg). Age-related increase in the carotid pulse pressure was statistically significant (p < 0.01). ROC analysis yielded carotid pressure cutoffs of 111/80 mmHg to categorize hypertensives. In view of the demonstrated functionality, the device is a reliable, easy-to-use tool for high-throughput screening applications.

要約(英語): We present a method for evaluating blood pressure from the carotid artery using an image-free ultrasound device ? ARTSENS. It was validated on 390 subjects (45±10 years) from the urban, rural, and semi-urban regions in India. In compliance with theory, the carotid pulse pressure (25.3±9.4 mmHg) and systolic pressure (99.4±16.5 mmHg) were significantly lower (p<0.0001) than those of the brachial artery (39.7±14.2 mmHg, 113.7±20.0 mmHg). Age-related increase in the carotid pulse pressure was statistically significant (p < 0.01). ROC analysis yielded carotid pressure cutoffs of 111/80 mmHg to categorize hypertensives. In view of the demonstrated functionality, the device is a reliable, easy-to-use tool for high-throughput screening applications.

本誌: 2021年3月26日-2021年3月27日通信研究会

本誌掲載ページ: 45-50 p

原稿種別: 英語

PDFファイルサイズ: 1,324 Kバイト

販売タイプ
書籍サイズ
ページ数
詳細を表示する