商品情報にスキップ
1 2

Measurement of lactate concentration using a minimally invasive needle with non-planner optical waveguides

Measurement of lactate concentration using a minimally invasive needle with non-planner optical waveguides

通常価格 ¥660 JPY
通常価格 セール価格 ¥660 JPY
セール 売り切れ
税込

カテゴリ: 研究会(論文単位)

論文No: MSS24025,CHS24007,BMS24003

グループ名: 【E】センサ・マイクロマシン部門 マイクロマシン・センサシステム/【E】センサ・マイクロマシン部門 ケミカルセンサ/【E】センサ・マイクロマシン部門 バイオ・マイクロシステム合同研究会

発行日: 2024/03/25

タイトル(英語): Measurement of lactate concentration using a minimally invasive needle with non-planner optical waveguides

著者名: KOIWA DAIGO(TOHOKU University),MORI KEIGO(TOHOKU University),HAGA YOICHI(TOHOKU University),TSURUOKA NORIKO(TOHOKU University)

著者名(英語): DAIGO KOIWA(TOHOKU University),KEIGO MORI(TOHOKU University),YOICHI HAGA(TOHOKU University),NORIKO TSURUOKA(TOHOKU University)

キーワード: Optical waveguide|Non-planar photofabrication process|Minimally invasive biological substances measurement|Absorbance measurement|wall window|Lactate concentration measurement|Optical waveguide|Non-planar photofabrication process|Minimally invasive biolog

要約(日本語): Two optical waveguides were fabricated on the surface of a thin acupuncture needle to measure the concentration of biological substances in skin tissue using near-infrared light absorption. The optical waveguides have a core of SU-8 surrounded by aluminum that totally reflects light. The SU-8 was patterned on the surface of the acupuncture needle using the developed non-planar photo fabrication method and the aluminum was sputtered and patterned. A light transmitting/receiving windows were fabricated on the wall surface between the two optical waveguides and the lactate concentration was measured using the fabricated needle.

要約(英語): Two optical waveguides were fabricated on the surface of a thin acupuncture needle to measure the concentration of biological substances in skin tissue using near-infrared light absorption. The optical waveguides have a core of SU-8 surrounded by aluminum that totally reflects light. The SU-8 was patterned on the surface of the acupuncture needle using the developed non-planar photo fabrication method and the aluminum was sputtered and patterned. A light transmitting/receiving windows were fabricated on the wall surface between the two optical waveguides and the lactate concentration was measured using the fabricated needle.

本誌: 2024年3月28日-2024年3月30日マイクロマシン・センサシステム/ケミカルセンサ/バイオ・マイクロシステム合同研究会

本誌掲載ページ: 7-11 p

原稿種別: 英語

PDFファイルサイズ: 1,427 Kバイト

販売タイプ
書籍サイズ
ページ数
詳細を表示する