Installation of PA66, PMMA or Si-resin cylinders in silica-sand for rising arc voltage during DC interruption

Installation of PA66, PMMA or Si-resin cylinders in silica-sand for rising arc voltage during DC interruption

通常価格 ¥330 JPY
通常価格 セール価格 ¥330 JPY
セール 売り切れ
税込

カテゴリ: 研究会(論文単位)

論文No: ED18098

グループ名: 【A】基礎・材料・共通部門 放電研究会

発行日: 2018/11/03

タイトル(英語): Installation of PA66, PMMA or Si-resin cylinders in silica-sand for rising arc voltage during DC interruption

著者名: Kodama Naoto(Nagoya University),Yokomizu Yasunobu(Nagoya University),Takahashi Asato(Nagoya University),Nakamura Koya(Nagoya University),Ueda Yusuke(Nagoya University),Kondo Yusuke(Pacific Engineering Corporation)

著者名(英語): Naoto Kodama(Nagoya University),Yasunobu Yokomizu(Nagoya University),Asato Takahashi(Nagoya University),Koya Nakamura(Nagoya University),Yusuke Ueda(Nagoya University),Yusuke Kondo(Pacific Engineering Corporation)

キーワード: DC arc|Fuse|Polymer|DC interruption|Chemical composition|DC arc|Fuse|Polymer|DC interruption|Chemical composition

要約(日本語): Experiments of DC interruption were carried out in an arc quenching chamber filled with silica-sand. PA66, PMMA or Si-resin cylinders were installed between the electrodes. A damping DC with peak current of 1000 A was supplied as test current. As a result of PA66 installation, an arc voltage rose compared with that for no-polymer installation. Increase in the arc voltage was also found for PMMA or Si-resin installation. In addition, an atomization enthalpy of the polymer was uniquely defined and calculated based on chemical structure of the polymer. The increase in the arc voltage resulting from polymer-material installation could be explained on the basis of the atomization enthalpy of polymers

要約(英語): Experiments of DC interruption were carried out in an arc quenching chamber filled with silica-sand. PA66, PMMA or Si-resin cylinders were installed between the electrodes. A damping DC with peak current of 1000 A was supplied as test current. As a result of PA66 installation, an arc voltage rose compared with that for no-polymer installation. Increase in the arc voltage was also found for PMMA or Si-resin installation. In addition, an atomization enthalpy of the polymer was uniquely defined and calculated based on chemical structure of the polymer. The increase in the arc voltage resulting from polymer-material installation could be explained on the basis of the atomization enthalpy of polymers