A Bipolar-Switched Three-Level T-type Inverter to Suppress Neutral-Point Voltage Ripple
A Bipolar-Switched Three-Level T-type Inverter to Suppress Neutral-Point Voltage Ripple
カテゴリ: 研究会(論文単位)
論文No: PE19055
グループ名: 【B】電力・エネルギー部門 電力技術研究会
発行日: 2019/09/10
タイトル(英語): A Bipolar-Switched Three-Level T-type Inverter to Suppress Neutral-Point Voltage Ripple
著者名: Lee Tzung-Lin(National Sun Yat-sen University),Wu Ting-Lien(National Sun Yat-sen University),Chuang Bing-Rong(National Sun Yat-sen University)
著者名(英語): Tzung-Lin Lee(National Sun Yat-sen University),Ting-Lien Wu(National Sun Yat-sen University),Bing-Rong Chuang(National Sun Yat-sen University)
キーワード: Three-level T-type inverter|photovoltaic generation|neutral-point oscillation|Three-level T-type inverter|photovoltaic generation|neutral-point oscillation
要約(日本語): In recent years, three-level T-type inverter has been widely applied in solar power generation systems, however, the traditional modulation method will result in the triple-fundamental-frequency oscillation at the neutral point of T-type inverter. It will affect the maximum power point tracking of solar cell strings. Therefore, a hybrid modulation strategy is proposed in this paper, the proposed hybrid modulation strategy can effectively suppress the triple- fundamental-frequency oscillation at the neutral point of T-type inverter and film capacitors are able to replace electrolytic capacitors to increase the lifetime of the inverter. experimental result are provided to verify the proposed modulating method.
要約(英語): In recent years, three-level T-type inverter has been widely applied in solar power generation systems, however, the traditional modulation method will result in the triple-fundamental-frequency oscillation at the neutral point of T-type inverter. It will affect the maximum power point tracking of solar cell strings. Therefore, a hybrid modulation strategy is proposed in this paper, the proposed hybrid modulation strategy can effectively suppress the triple- fundamental-frequency oscillation at the neutral point of T-type inverter and film capacitors are able to replace electrolytic capacitors to increase the lifetime of the inverter. experimental result are provided to verify the proposed modulating method.
原稿種別: 英語
PDFファイルサイズ: 1,921 Kバイト