商品情報にスキップ
1 1

ESDガンの異なった配置に対する接触放電で注入される放電電流波形とパワスペクトルのばらつき

ESDガンの異なった配置に対する接触放電で注入される放電電流波形とパワスペクトルのばらつき

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【A】基礎・材料・共通部門

発行日: 2011/05/01

タイトル(英語): Variations in Discharge Current Waveforms and its Power Spectra Injected from Contact Discharges of ESD-Gun with Different Arrangements

著者名: 高 義礼(名古屋工業大学大学院),藤原 修(名古屋工業大学大学院)

著者名(英語): Yoshinori Taka (Graduate School of Engineering, Nagoya Institute of Technology), Osamu Fujiwara (Graduate School of Engineering, Nagoya Institute of Technology)

キーワード: ESDガン,接触放電,放電電流波形,パワスペクトル,ばらつき  ESD-gun,contact discharge,discharge current waveform,power spectrum,variation

要約(英語): The International Electrotechnical Commission (IEC) has prescribed an immunity test (IEC61000-4-2) of electronic equipment against electrostatic discharges (ESDs), in which a discharge current to be injected onto equipment under test is specified. As for the waveform, however, not the whole waveform but only the rise time, the first peak, and the current amplitudes at 30 ns and 60 ns are given in the time domain together with their uncertainties, which are required to check on the condition that an ESD generator (ESD-gun) shall be arranged vertically to an IEC recommended calibration target and its earth return wire is kept away as far as possible from a vertical ground plane (IEC standard arrangement). In this study, to clarify how arrangements of an ESD-gun and its earth return wire affect discharge currents, we measured discharge current waveforms for contact discharges of an ESD-gun onto an IEC calibration target with respect to various inclinations of the ESD-gun and arrangements of its earth return wire, and also calculated their current power spectra normalized to that of the discharge current for the IEC standard arrangement. As a result, we found that inclinations of the ESD gun affect the first peak current, which increases current power spectra by 14 dB at frequencies over 300 MHz, and that arrangements of the return wire influence the current waveforms between the first and second peaks, which provides variations in power spectra by ±12 dB in the frequency range from 10 MHz to 200 MHz. This finding suggests that arrangements of an ESD gun and its earth return wire are likely to cause different immunity test results. It was also found that in comparison with measured discharge currents for the standard arrangement, the calculated waveform of a discharge current from a formula, which has been included in the recent standard, has a more gentle falling waveform, and produces power spectra of +15dB in the frequency range from 10 MHz to 200 MHz and -12 dB at frequencies over 300 MHz.

本誌: 電気学会論文誌A(基礎・材料・共通部門誌) Vol.131 No.5 (2011) 特集:光源・照明の新潮流

本誌掲載ページ: 384-388 p

原稿種別: 論文/日本語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejfms/131/5/131_5_384/_article/-char/ja/

販売タイプ
書籍サイズ
ページ数
詳細を表示する