ESDガンのIEC較正用電流検出変換器に対する伝達インピーダンスの測定と検証

ESDガンのIEC較正用電流検出変換器に対する伝達インピーダンスの測定と検証

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【A】基礎・材料・共通部門

発行日: 2012/05/01

タイトル(英語): Measurement and Validation of Transfer Impedance of IEC Calibration Current Target for Electrostatic Discharge Generators

著者名: 山中 幸雄((独) 情報通信研究機構),足立 貴士(名古屋工業大学大学院),石上 忍((独) 情報通信研究機構),森 育子(鈴鹿工業高等専門学校電子情報工学科),高 義礼(釧路高等専門学校電子工学科),藤原 修(名古屋工業大学大学院)

著者名(英語): Yukio Yamanaka (National Institute of Information and Communications Technology), Takashi Adachi (Nagoya Institute of Technology), Shinobu Ishigami (National Institute of Information and Communications Technology), Ikuko Mori (Department of Electronic and Information Engineering, Suzuka National College of Technology), Yoshinori Taka (Department of Electronic Engineering, Kushiro National College of Technology), Osamu Fujiwara (Nagoya Institute of Technology)

キーワード: ESDガン,IEC電流検出変換器,伝達インピーダンス,注入電流,再構成  electrostatic discharge generators,IEC calibration current target,transfer impedance,injection current,reconstruction

要約(英語): In the present study, using a 50Ω tapered coaxial type adapter and a S-parameter technique, we measured the transfer impedance of a commercially available IEC calibration current target used for the immunity testing against electrostatic discharges (ESDs), which is being prescribed in the International Electrotechnical Commission (IEC) 61000-4-2, and thereby reconstructed the waveforms of discharge currents injected onto the target from their observed output voltages for contact and air discharges of an ESD generator. As a result, we found that the transfer impedance is almost 1+j0Ω at frequencies below 1GHz, while due to resonance phenomena occurring at frequencies around 2GHz and 5GHz, resistive and reactive components significantly change at frequencies over 1GHz, though their absolute values are slightly larger than 1Ω. This result has revealed that the reconstructed discharge currents agree well with the observed voltages with a rise time of almost 1ns for the contact discharges and air discharges with slow approach of an ESD gun with charge voltages above 2kV, while in the case for the observed voltage with a rapid rise time shorter than a hundred pico-seconds for the air discharges with fast approach, the reconstructed discharge current has a bit gentle rising slope and a slightly lower level of the first current peak.

本誌: 電気学会論文誌A(基礎・材料・共通部門誌) Vol.132 No.5 (2012) 特集:静電気放電(ESD)のEMC技術

本誌掲載ページ: 350-355 p

原稿種別: 論文/日本語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejfms/132/5/132_5_350/_article/-char/ja/