商品情報にスキップ
1 1

An Analysis of the Initial Breakdown Pulses for Positive Cloud-to-Ground Flashes

An Analysis of the Initial Breakdown Pulses for Positive Cloud-to-Ground Flashes

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【B】電力・エネルギー部門

発行日: 2012/06/01

タイトル(英語): An Analysis of the Initial Breakdown Pulses for Positive Cloud-to-Ground Flashes

著者名: Yang Zhang (Laboratory of Lightning Physics and Protection Engineering, Chinese Academy of Meteorological Sciences), Yijun Zhang (Laboratory of Lightning Physics and Protection Engineering, Chinese Academy of Meteorological Sciences), Weitao Lu (Laborator

著者名(英語): Yang Zhang (Laboratory of Lightning Physics and Protection Engineering, Chinese Academy of Meteorological Sciences), Yijun Zhang (Laboratory of Lightning Physics and Protection Engineering, Chinese Academy of Meteorological Sciences), Weitao Lu (Laboratory of Lightning Physics and Protection Engineering, Chinese Academy of Meteorological Sciences), Dong Zheng (Laboratory of Lightning Physics and Protection Engineering, Chinese Academy of Meteorological Sciences)

キーワード: initial breakdown pulse,positive cloud-to-ground flashes,distribution,polarity

要約(英語): In order to further understand the initiating mechanism of positive cloud-to-ground (PCG) flashes, the characteristics of initial breakdown pulse trains are investigated by using electric field data of Guangdong province. Considering the difference in initial polarity between the initial breakdown pulses and the first return stoke (RS), three types of bipolar pulse trains, including the same polarity (type I), the opposite polarity (type II) and the composite polarity (type III), are identified. The percentages of type I, type II and type III are about 84%, 10% and 6%, respectively. The statistical results show that PCG flashes including initial breakdown pulse trains, which occur frequently when PCG flashes are not active, are about 12% of all the PCG flashes. The width of individual pulse (Tpw) and the interval of adjacent pulses (Tpi) are about 25μs and 271μs, respectively. The mean values of pulse train duration (Td) and the interval (Tp-ri) between initial breakdown pulse train and RS are 8.88ms and 98.48ms, respectively. The average value of the ratio (Rp-rr) between the maximum amplitude of pulse train and the amplitude of the first stroke pulse is 0.16. The ratio is smaller in Guangzhou province than in Japan and in Brazil. Comparing of the parameters of type I and type II, it can be found that Tpw, Td and Tpi of type II are less than those of type I, however, the values of Tp-ri and Rp-rr of type II are larger than those of type I. The possible causes of the observating several types of pulse trains and the significantly diversified pulse characteristics are discussed.

本誌: 電気学会論文誌B(電力・エネルギー部門誌) Vol.132 No.6 (2012) 特集:冬季雷,正極性雷,高建造物への落雷(ISWL)

本誌掲載ページ: 542-547 p

原稿種別: 論文/英語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejpes/132/6/132_542/_article/-char/ja/

販売タイプ
書籍サイズ
ページ数
詳細を表示する