非平衡MHD発電機の発電性能に及ぼす高周波誘導コイルの非対称配置の影響
非平衡MHD発電機の発電性能に及ぼす高周波誘導コイルの非対称配置の影響
カテゴリ: 論文誌(論文単位)
グループ名: 【B】電力・エネルギー部門
発行日: 2013/09/01
タイトル(英語): Influence of Asymmetric Placement of Radio-Frequency Induction Coil on Performance of Nonequilibrium MHD Generator
著者名: 藤野 貴康(筑波大学大学院システム情報工学研究科構造エネルギー工学専攻),大谷 尚史(筑波大学大学院システム情報工学研究科構造エネルギー工学専攻),小南 晋(筑波大学大学院システム情報工学研究科構造エネルギー工学専攻),石川 本雄(筑波大学大学院システム情報工学研究科構造エネルギー工学専攻),奥野 喜裕(東京工業大学大学院総合理工学研究科創造エネルギー専攻)
著者名(英語): Takayasu Fujino (Department of Engineering Mechanics and Energy, Graduate School of Systems and Information Engineering, University of Tsukuba), Naofumi Ooya (Department of Engineering Mechanics and Energy, Graduate School of Systems and Information Engineering, University of Tsukuba), Susumu Kominami (Department of Engineering Mechanics and Energy, Graduate School of Systems and Information Engineering, University of Tsukuba), Motoo Ishikawa (Department of Engineering Mechanics and Energy, Graduate School of Systems and Information Engineering, University of Tsukuba), Yoshihiro Okuno (Department of Energy Sciences, Tokyo Institute of Technology)
キーワード: 商用規模非平衡MHD発電機,高周波予備電離,電磁流体解析 commercial scale nonequilibrium MHD generator,rf preionization,MHD numerical simulation
要約(英語): The authors conduct a two-dimensional (r-z) MHD numerical simulation for examining the influence of asymmetric placement of radio-frequency (rf) induction coil on the generator performance of a commercial scale, large nonequilibrium disk-shaped MHD generator with an rf preionization technique. The MHD numerical simulation is carried out under two different placement conditions of rf induction coil: one is that an rf induction coil is placed on only one side disk wall and the other is that it is symmetrically placed on each of both disk walls. Numerical results show the performance of MHD generator with one-sided rf induction coil placement inducing an asymmetric rf electromagnetic (EM) field is comparable to that of the MHD generator with both-sided rf indction coil placement inducing a symmetric rf EM field, although the one-sided induction rf coil placement causes an asymmetric distribution in the z-direction of plasma properties such as electron temperature and ionization degree near the rf induction coil.
本誌: 電気学会論文誌B(電力・エネルギー部門誌) Vol.133 No.9 (2013)
本誌掲載ページ: 707-715 p
原稿種別: 論文/日本語
電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejpes/133/9/133_707/_article/-char/ja/