変調光と位相検波器を用いたモジュール内セル電圧の非接触推定
変調光と位相検波器を用いたモジュール内セル電圧の非接触推定
カテゴリ: 論文誌(論文単位)
グループ名: 【B】電力・エネルギー部門
発行日: 2018/01/01
タイトル(英語): Contactless Estimation of a Solar Cell Voltage in a Module using Modulated Light and a Phase Detector
著者名: 小林 靖之(帝京大学 理工学部),菊元 大地((株)情報技研)
著者名(英語): Yasuyuki Kobayashi (Faculty of Science and Engineering, Teikyo University), Daichi Kikumoto (Jouhou Giken, Ltd.)
キーワード: 太陽光発電,モジュール,変調光,位相検波器,非接触\photovoltaics,module,modulated light,phase detector,contactless
要約(英語): As a solar cell connected in series in a solar module fails, the operating module current decreases, however the operating voltage of each cell is not measurable if the cells are sealed tightly in the module. This research proposes a method to estimate an operating cell voltage in a module by irradiating modulated light to the cell and detecting the modulated signal from a load resistance of the module by a phase detector. And experiments for a small scale module to confirm the method have showed that the modulated signal detected by the phase detector increases as an operating cell voltage decreases, as expected according to the proposed theory. Therefore, it is confirmed in principle that the proposed method can estimate an operating cell voltage in a module.
本誌: 電気学会論文誌B(電力・エネルギー部門誌) Vol.138 No.1 (2018)
本誌掲載ページ: 45-52 p
原稿種別: 論文/日本語
電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejpes/138/1/138_45/_article/-char/ja/