SF6ガス絶縁電力機器の空気による内部アーク代替試験法の検討― 空気の初期充填ガス圧力値の設定方法―
SF6ガス絶縁電力機器の空気による内部アーク代替試験法の検討― 空気の初期充填ガス圧力値の設定方法―
カテゴリ: 論文誌(論文単位)
グループ名: 【B】電力・エネルギー部門
発行日: 2018/11/01
タイトル(英語): Study of Alternative Test Method of Internal Arcing by Replacing SF6 with Air in SF6-Insulated Power Equipment― Method of Configuring Initial Filling Gas Pressure of Air―
著者名: 神足 将司((一財)電力中央研究所 電力技術研究所),田所 兼((一財)電力中央研究所 電力技術研究所),田中 慎一((一財)電力中央研究所 電力技術研究所),岩田 幹正((一財)電力中央研究所 電力技術研究所)
著者名(英語): Masashi Kotari (Electric Power Engineering Research Lab., Central Research Institute of Electric Power Industry (CRIEPI)), Tomo Tadokoro (Electric Power Engineering Research Lab., Central Research Institute of Electric Power Industry (CRIEPI)), Shin-ichi
キーワード: 空気,SF6ガス,内部アーク代替試験法,密閉容器内部圧力,初期充填ガス圧力値,電極溶損 air,sulfur hexafluoride,alternative test method of internal arcing,pressure in a closed container,initial filling gas pressure,melting loss of electrodes
要約(英語): To develop an alternative test method for internal arc in SF6-insulataed power equipment, it is necessary to propose a specific procedure to replace SF6 with air and to select appropriate parameters for the tests. When carrying out the internal arc tests, it is necessary to select current, frequency, duration of current, initial filling gas pressure, and the point of arc initiation. In this paper, we conducted experiments on air and SF6 arcing in a closed container, and described the effect of the initial filling gas gauge pressure (Pini) in the container on melting loss of electrodes. Additionally, we focused on a sum of Pini and pressure rise (ΔPmax) due to arcing (Ptotal), and experimentally clarified that Ptotal of SF6 was equal to that of air by selecting the appropriate Pini of air. In the experiments, the arcs were ignited between rod electrodes by applying a current with a peak of 11kA and a duration of 40ms. The rod electrodes were made of copper, iron, and aluminum. As a result, in the case of Pini =0.5MPa(G), it was found that the amount of melting loss of any material electrode is almost equal on air and SF6. Also, in the case of air, it was clarified that the amount of melting loss of any material electrode is independent of Pini of air. Subsequently, it was experimentally clarified that Ptotal of SF6 was approximately equal to that of air by selecting Pini =0.35MPa(G)~0.4MPa(G) of air.
本誌: 電気学会論文誌B(電力・エネルギー部門誌) Vol.138 No.11 (2018)