Reactive Power Demand Response for Distribution System with Neighboring Clusters of Building Multi-type Air-conditioners

Reactive Power Demand Response for Distribution System with Neighboring Clusters of Building Multi-type Air-conditioners

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【B】電力・エネルギー部門

発行日: 2022/06/01

タイトル(英語): Reactive Power Demand Response for Distribution System with Neighboring Clusters of Building Multi-type Air-conditioners

著者名: Asif Iqbal (Smart Grid Power Control Engineering Joint Research Lab., Gifu University), Yoshifumi Aoki (Smart Grid Power Control Engineering Joint Research Lab., Gifu University), Chuzo Ninagawa (Smart Grid Power Control Engineering Joint Research Lab., G

著者名(英語): Asif Iqbal (Smart Grid Power Control Engineering Joint Research Lab., Gifu University), Yoshifumi Aoki (Smart Grid Power Control Engineering Joint Research Lab., Gifu University), Chuzo Ninagawa (Smart Grid Power Control Engineering Joint Research Lab., Gifu University), Takayoshi Murakawa (Advanced Research & Innovation Center, Chubu Electric Power Company)

キーワード: building multi-type air-conditioner,reactive power,demand response,DERMS

要約(英語): Recently, the technology of controlling the demand-side reactive power to stabilize a power distribution system has been attracting attention. Since building multi-type air-conditioners are widely installed in office buildings, they have the potential to participate in distribution system stabilization if they can fulfill the request of the reactive power demand response. This paper proposes a new approach of reactive power demand response using building multi-type air-conditioners in a cluster of neighboring office buildings near the feeder location where a voltage deviation problem has occurred. We define a set of operation modes for the active converter built-in each air-conditioner to inject/absorb the reactive power. Next, we propose a new method of reactive power allocation to each air-conditioner taking into account each air-conditioning load and comfort. An integrated simulator has been developed combining our model of air-conditioner's transient behaviors and a model of the standard urban distribution system. The simulation result has shown, for example, a neighboring cluster of 25 air-conditioners in 5 office buildings continued the aggregated reactive power injection of approximately 400kvar for 10 minutes while maintaining room-temperatures within the comfort range.

本誌: 電気学会論文誌B(電力・エネルギー部門誌) Vol.142 No.6 (2022)

本誌掲載ページ: 306-314 p

原稿種別: 論文/英語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejpes/142/6/142_306/_article/-char/ja/