商品情報にスキップ
1 1

在席状況に基づくオフィス照明調光制御システムの開発

在席状況に基づくオフィス照明調光制御システムの開発

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【C】電子・情報・システム部門

発行日: 2013/07/01

タイトル(英語): An Office Lighting Control System based on Employee Entry/Exit State

著者名: 金子 洋介(三菱電機(株) 情報技術総合研究所),北上 眞二(三菱電機(株) 情報技術総合研究所),安田 晃久(三菱電機(株) 情報技術総合研究所),竹中 友哉(三菱電機(株) 情報技術総合研究所),松下 雅仁(三菱電機(株) 情報技術総合研究所),小泉 寿男(東京電機大学)

著者名(英語): Yosuke Kaneko (Information Technology R&D Center, Mitsubishi Electric Corporation), Shinji Kitagami (Information Technology R&D Center, Mitsubishi Electric Corporation), Akihisa Yasuda (Information Technology R&D Center, Mitsubishi Electric Corporation), Tomoya Takenaka (Information Technology R&D Center, Mitsubishi Electric Corporation), Masahito Matsushita (Information Technology R&D Center, Mitsubishi Electric Corporation), Hisao Koizumi (Tokyo Denki University)

キーワード: 照明,オフィスビル,調光制御,社員の入退室,省エネ,実証評価  lighting,office building,illuminance control,employee entry and exit,energy-saving,experimental evaluation

要約(英語): Lighting control systems have been proposed for energy conservation because lighting accounts for not less than 30% of electrical power consumption in a typical office building. Herein, we propose an office-lighting dimming control system based on employee entry and exit from a room. A spot illuminance control method determines the dimming rate that will satisfy every employee's illumination needs. The system adjusts the dimming rate to negate the influence that the spot illuminance control for an employee gives to other employees. These methods offer the illuminance necessary and sufficient only to the sitting employee's area according to the change of employee entry and exit in a room. In order to evaluate proposed method, we produced a lighting control system and applied the proposed method in part of an office building, corresponding to about 300m2. We evaluated the error of measured illuminance compared with the target illuminance after control, and assessed the energy-saving effect. By the results of experimental evaluations, we confirmed that the difference in target illuminance and measurement illuminance is small enough not be able to recognize by employee, the energy-saving effect is 24.3% compared with the wall light switch operation, and the operation speed of proposed method is fast enough for the frequency of employee entry and exit in a room.

本誌: 電気学会論文誌C(電子・情報・システム部門誌) Vol.133 No.7 (2013) 特集:平成24 年電気学会電子・情報・システム部門大会

本誌掲載ページ: 1356-1366 p

原稿種別: 論文/日本語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejeiss/133/7/133_1356/_article/-char/ja/

販売タイプ
書籍サイズ
ページ数
詳細を表示する