商品情報にスキップ
1 1

Near Real-time Measurement of Myocardial Contraction and Relaxation Based on High-frame-rate Ultrasound with a Graphical Processing Unit System

Near Real-time Measurement of Myocardial Contraction and Relaxation Based on High-frame-rate Ultrasound with a Graphical Processing Unit System

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【C】電子・情報・システム部門

発行日: 2017/04/01

タイトル(英語): Near Real-time Measurement of Myocardial Contraction and Relaxation Based on High-frame-rate Ultrasound with a Graphical Processing Unit System

著者名: Takuma Asai (Graduate School of Biomedical Engineering, Tohoku University), Hirofumi Taki (Graduate School of Biomedical Engineering, Tohoku University), Hiroshi Kanai (Graduate School of Engineering, Tohoku University)

著者名(英語): Takuma Asai (Graduate School of Biomedical Engineering, Tohoku University), Hirofumi Taki (Graduate School of Biomedical Engineering, Tohoku University), Hiroshi Kanai (Graduate School of Engineering, Tohoku University)

キーワード: speckle tracking,myocardial contraction/relaxation property,two-dimensional (2D) displacement estimation,graphical processing unit (GPU)

要約(英語): Several speckle tracking methods have been proposed for noninvasive and quantitative evaluation of tissue motion. Since the low temporal resolution causes a large myocardial motion in the elevational direction and a large deformation, two-dimensional (2D) speckle tracking at a high frame rate is desirable for accurate estimation of myocardial contraction and relaxation. 2D speckle tracking at a high frame rate requires a high computational load, and the large suppression of calculation time is, therefore, essential for clinical use. In the present study, we investigate the minimum frame rate required for the estimation of myocardial contraction and relaxation. Furthermore, we employ a parallel computing principle using a graphical processing unit (GPU) system with 2,496 streaming processors to decrease the calculation time effectively. The employment of a parallel computing principle with a GPU system successfully decreased the calculation time to 1/50 of that using a desktop PC with a CPU. When the number of tracking points is 64, the calculation time was decreased to 28.7 s for the estimation during 1 s at a frame rate of 287 Hz, indicating that the proposed method with a GPU system has a potential to realize a near real-time estimation of myocardial contraction and relaxation.

本誌: 電気学会論文誌C(電子・情報・システム部門誌) Vol.137 No.4 (2017) 特集:量子・情報・エレクトロニクス医療応用

本誌掲載ページ: 573-578 p

原稿種別: 論文/英語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejeiss/137/4/137_573/_article/-char/ja/

販売タイプ
書籍サイズ
ページ数
詳細を表示する