双方向絶縁形DC-DCコンバータ(750V, 100kW, 20kHz)の効率改善と過渡特性
双方向絶縁形DC-DCコンバータ(750V, 100kW, 20kHz)の効率改善と過渡特性
カテゴリ: 論文誌(論文単位)
グループ名: 【D】産業応用部門
発行日: 2019/07/01
タイトル(英語): Efficiency Improvement and Transient Characteristics of the 750-V, 100-kW, 20-kHz Bidirectional Isolated DC-DC Converter
著者名: 羽根田 崚(東京工業大学 工学院 電気電子系),赤木 泰文(東京工業大学 工学院 電気電子系)
著者名(英語): Ryo Haneda (Department of Electrical and Electronic Engineering, Tokyo Institute of Technology), Hirofumi Akagi (Department of Electrical and Electronic Engineering, Tokyo Institute of Technology)
キーワード: 双方向絶縁形DC-DCコンバータ,高効率化,間欠運転,過渡特性 bidirectional isolated dc-dc converters,enhancement of power conversion efficiency,intermittent operation,transient characteristics
要約(英語): This paper describes the 750-V, 100-kW, 20-kHz bidirectional isolated dual-active-bridge (DAB) dc-dc converter using the latest 1.2-kV, 400-A SiC-MOSFET 4-in-1 modules integrated with SBDs. It focuses on power conversion efficiency and transient characteristics. This dc-dc converter is characterized by being capable of an appropriate switchover between continuous operation and intermittent operation for the purpose of efficiency improvement. The intermittent operation achieves more efficient power conversion for partial loads than does the continuous operation. However, the intermittent operation may cause different upper and lower peak currents in the converter, thus resulting in an increase in the amount of switching loss. This paper introduces an advanced control method for the intermittent operation, which improves the efficiency. Experimental results reveal that the advanced method improves the efficiency from 98.4% in the previous method to 98.6% at 22kW. The efficiency in continuous operation at 100kW is 98.3% in the case of using the previous four 2-in-1 modules without SBD, while it is improved to 98.9% in the case of using the two 4-in-1 modules. Experimental transient characteristics show that no dc magnetic-flux bias occurs even during switchover between continuous and intermittent operation when power reversal from -100kW to 100kW occurs within a time interval of 1ms. Finally, it is verified that the dc-dc converter is capable of providing fast power-reversing performance from -100kW to 100kW within a time interval as short as 25μs.
本誌: 電気学会論文誌D(産業応用部門誌) Vol.139 No.7 (2019)
本誌掲載ページ: 657-664 p
原稿種別: 論文/日本語