商品情報にスキップ
1 1

Voltage Control of Intermittent Pulse Density Modulation for Two Battery-operated HEECS Choppers and its Application for Range Extension of Electric Vehicles

Voltage Control of Intermittent Pulse Density Modulation for Two Battery-operated HEECS Choppers and its Application for Range Extension of Electric Vehicles

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【D】産業応用部門(英文)

発行日: 2019/09/01

タイトル(英語): Voltage Control of Intermittent Pulse Density Modulation for Two Battery-operated HEECS Choppers and its Application for Range Extension of Electric Vehicles

著者名: Ayataro Tamura (Graduate School of Engineering, Yokohama National University), Takayuki Ishibashi (Graduate School of Engineering, Yokohama National University), Takuro Umihara (Graduate School of Engineering, Yokohama National University), Yukinori Tsuru

著者名(英語): Ayataro Tamura (Graduate School of Engineering, Yokohama National University), Takayuki Ishibashi (Graduate School of Engineering, Yokohama National University), Takuro Umihara (Graduate School of Engineering, Yokohama National University), Yukinori Tsuruta (Graduate School of Engineering, Yokohama National University), Hidemine Obara (Graduate School of Engineering, Yokohama National University), Atsuo Kawamura (Graduate School of Engineering, Yokohama National University)

キーワード: voltage control,electric vehicle,power train,buck chopper,motor test bench,power electronics

要約(英語): This paper proposes voltage control of two battery-operated high-efficiency energy conversion system choppers, which have a very high efficiency of 99.3% and are suitable for power trains of electrical vehicles. However, due to the topology of the choppers, one disadvantage is that the chopper output voltage control has a large transient response, for example, when the duty ratio is changed from zero to a finite value, because of the inherent dead time in the switching phenomena. The minimum pulse width of the gate signal is physically determined by the delay time in the switching phenomena. As a result, there exists a dead time when the duty ratio is changed in this case. Similar phenomena occur when the duty ratio is changed around unity. Consequently, an overcurrent is observed during these types of transient periods and the system shuts down due to overcurrent protection. To solve this problem, intermittent pulse density modulation is proposed such that the output voltage is controlled by the average duty ratio. This makes it possible to output both the very low and the very high average duty ratios with multiple sampling periods. As a result, the transient response was experimentally verified to be improved even though the voltage ripple under this control increased compared with that under simple pulse width modulation (PWM) control.

本誌: IEEJ Journal of Industry Applications Vol.8 No.5 (2019)

本誌掲載ページ: 787-794 p

原稿種別: 論文/英語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejjia/8/5/8_787/_article/-char/ja/

販売タイプ
書籍サイズ
ページ数
詳細を表示する