商品情報にスキップ
1 1

An Auto-Tuning Damper for the Harmonic Resonance of Grid-Connected Converters

An Auto-Tuning Damper for the Harmonic Resonance of Grid-Connected Converters

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【D】産業応用部門(英文)

発行日: 2019/11/01

タイトル(英語): An Auto-Tuning Damper for the Harmonic Resonance of Grid-Connected Converters

著者名: Chia-Tse Lee (Research and Development Group, Hitachi, Ltd.), Akira Kikuchi (Research and Development Group, Hitachi, Ltd.), Tomomichi Ito (Research and Development Group, Hitachi, Ltd.)

著者名(英語): Chia-Tse Lee (Research and Development Group, Hitachi, Ltd.), Akira Kikuchi (Research and Development Group, Hitachi, Ltd.), Tomomichi Ito (Research and Development Group, Hitachi, Ltd.)

キーワード: power converter,system impedance variations,on-line detection,harmonics,resonances suppression,damping control

要約(英語): An auto-tuning damper for grid-connected converters (GCs) is proposed in this paper to improve the stability of GCs when there is an increase in the penetration of renewable energy sources (RES). Increasing number of GCs are being connected to the power grid for supporting the power generation of RES systems, and this makes the equivalent output impedance of GCs becomes closer to the system impedance of the power grid. This increases the influences of the operation of GCs on the output voltage, and there is a greater risk of GCs becoming instable. In addition, system operations such as switching of transmission lines will result in larger variations in the system impedance than before in this situation. This could induce large changes in the resonance characteristics between the system and GCs. In this situation, conventional active damping control, which is designed based on the known conditions of system impedance, could have less controllability due to the changes in resonance characteristics. The harmonic resonance could become instable if the active damping control has insufficient damping effect. For this reason, an auto-tuning damper for harmonic resonance is proposed in this paper. It makes the active damping control capable of taking action in response to the changes in resonance characteristics. Therefore, it can improve the stability of operation of GCs. The operational principle, simulation, and scale-down prototype validation are presented to show the improvements achieved by the proposed solution. In addition, a problem investigated during prototype validation is explained and described.

本誌: IEEJ Journal of Industry Applications Vol.8 No.6 (2019)

本誌掲載ページ: 884-892 p

原稿種別: 論文/英語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejjia/8/6/8_884/_article/-char/ja/

販売タイプ
書籍サイズ
ページ数
詳細を表示する