溶融ブリッジの溶融蒸発とアークの発弧が及ぼすトロリ線の溶融量算出手法の開発
溶融ブリッジの溶融蒸発とアークの発弧が及ぼすトロリ線の溶融量算出手法の開発
カテゴリ: 論文誌(論文単位)
グループ名: 【D】産業応用部門
発行日: 2022/05/01
タイトル(英語): Development of Calculation Method for Melting Amount Mass of Contact Wire Caused by Melting and Evaporation of Molten Metal Bridge and Arc Generation
著者名: 森下 穂香(東京都市大学大学院 総合理工学研究科 電気・化学専攻),真栄田 義史(東京都市大学大学院 総合理工学研究科 電気・化学専攻),任 振威(東京都市大学大学院 総合理工学研究科 電気・化学専攻),根本 雄介(東京都市大学大学院 総合理工学研究科 電気・化学専攻),早坂 高雅(鉄道総合技術研究所),岩尾 徹(東京都市大学 理工学部 電気電子通信工学科)
著者名(英語): Honoka Morishita (Electrical Engineering and Chemistry, Graduate School of Integrative Science and Engineering, Tokyo City University), Yoshifumi Maeda (Electrical Engineering and Chemistry, Graduate School of Integrative Science and Engineering, Tokyo City University), Zhenwei Ren (Electrical Engineering and Chemistry, Graduate School of Integrative Science and Engineering, Tokyo City University), Yusuke Nemoto (Electrical Engineering and Chemistry, Graduate School of Integrative Science and Engineering, Tokyo City University), Takamasa Hayasaka (Railway Technical Research Institute), Toru Iwao (Department of Electrical, Electronics and Communication Engineering, Faculty of Science and Engineering, Tokyo City University)
キーワード: 3次元電磁熱流体シミュレーション,離線アーク,トロリ線,溶融量_x000D_ three-dimensional electromagnetic thermal fluid simulation,disconnection arc,contact wire,melting amount mass
要約(英語): As the mileage of the electric railway increases, the unevenness of the contact wire may separate the contact wire and the contact strip. Simultaneously, a disconnection arc discharge is generated by the molten metal bridge. This causes the contact wire to melt and evaporate causing it to break. A few studies have conducted experiments to prevent the contact wire from disconnecting. Based on the results thus obtained, they presented their hypotheses considering conditions such as the current and time required for melting and evaporation of molten metal bridge and arc generation. In this study, a calculation method for the melting amount mass of contact wire caused by melting and evaporation of molten metal bridge and arc generation is developed in order to elucidate the melting and disconnection phenomenon of the contact wire. Its mass increased when the currents from both sides of the contact wire were taken into consideration. Therefore, we obtained that the convection and radiation play an important role for calculation of the melting amount mass of contact wire.
本誌: 電気学会論文誌D(産業応用部門誌) Vol.142 No.5 (2022) 特集:2021年産業応用部門大会
本誌掲載ページ: 410-417 p
原稿種別: 論文/日本語
電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejias/142/5/142_410/_article/-char/ja/
受取状況を読み込めませんでした