シールドケーブルの遮へい性能向上に関する検討
シールドケーブルの遮へい性能向上に関する検討
カテゴリ: 論文誌(論文単位)
グループ名: 【D】産業応用部門
発行日: 2022/12/01
タイトル(英語): A Study on Improving Shielding Performance of Shielded Cable
著者名: 土田 崇((株)関電工)
著者名(英語): Takashi Tsuchida (KANDENKO Co., Lyd.)
キーワード: シールドケーブル,遮へい性能,銅パイプ法,トリアクシャル法,インパルス試験,EMC_x000D_ shielded cable,shielding effect,copper-pipe method,triaxial method,impulse test,EMC
要約(英語): With the developments in power electronics equipment, the electromagnetic environment has become severe for electronic equipment. In the smart facility field, the stable operation of electronic devices is indispensable, and noise countermeasures must to be improved. To suppress intrusive noise from cables, shielded cables are used in many cases. However, electromagnetic induction cannot be suppressed when the shield is grounded at one end, and when grounding both ends of the shield, current flows through the shield creating intrusive noise in the cable. That is, even if a shielded cable is used, a sufficient effect cannot be obtained. Therefore, as a countermeasure, this study prototypes and evaluates cables that combine double shielded cables with magnetic cores. Evaluations conducted using the copper pipe method, triaxial method, and impulse test confirm that the shielded performance improved by 10 to 30dB compared with the conventional shielded cable.
本誌: 電気学会論文誌D(産業応用部門誌) Vol.142 No.12 (2022) 特集:レジリエントな社会を実現するスマートファシリティ関連技術
本誌掲載ページ: 891-896 p
原稿種別: 論文/日本語
電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejias/142/12/142_891/_article/-char/ja/
受取状況を読み込めませんでした