MIMO and SISO Impedance-based Stability Assessment of a Distributed Power Source Dominated System
MIMO and SISO Impedance-based Stability Assessment of a Distributed Power Source Dominated System
カテゴリ: 論文誌(論文単位)
グループ名: 【D】産業応用部門(英文)
発行日: 2023/07/01
タイトル(英語): MIMO and SISO Impedance-based Stability Assessment of a Distributed Power Source Dominated System
著者名: Kazuki Ohuchi (Department of Electrical, Electronic and Communications Engineering, Toyo University), Yuko Hirase (Department of Electrical, Electronic and Communications Engineering, Toyo University), Marta Molinas (Department of Engineering Cybernetics,
著者名(英語): Kazuki Ohuchi (Department of Electrical, Electronic and Communications Engineering, Toyo University), Yuko Hirase (Department of Electrical, Electronic and Communications Engineering, Toyo University), Marta Molinas (Department of Engineering Cybernetics, Norwegian University of Science and Technology)
キーワード: advanced inverter,impedance,stability,transient responses
要約(英語): In modern power grids, many distributed generators (DGs) are connected via grid-connected inverters. Generally, the possibility of resonances among inverters and other equipment placed in proximity and the network itself must be analyzed in advance. However, it is often difficult to approach the problem for complex systems by using model-based techniques, as they require obtaining a linear approximate analytical model. The impedance-based stability analysis method provides a practical alternative to the linear model approximation method. It directly measures the impedances of the source and load subsystems and evaluates its stability using the Nyquist criteria. In this study, we assume a scenario in which grid-connected inverters with advanced inverter control, such as the virtual synchronous generator (VSG) control, will become the primary power source in the near future and focuses on the possibility of instability phenomena caused by (i) a large-scale system with long-distance transmission lines usingπ-sections and (ii) the output filter of DGs with the natural frequencies in high frequency band. Accordingly, the impact of the dominant grid-connected inverter on stability in a large, complex system is evaluated based on the impedance in both the dq (MIMO) and equivalent sequence (SISO) domains. The results suggest that grid-forming controls, such as VSG controls, may resonate with their output filters in the kHz band and that capacitance in long transmission lines cannot be ignored as they can cause system instability. Moreover, it is found that the unstable frequencies identified in the two eigenvalue loci of the dq impedance are also identified in the sequence domain impedance within a single Nyquist plot, further validating the presence of unstable frequencies.
本誌: IEEJ Journal of Industry Applications Vol.12 No.4 (2023) Special Issue on “IPEC-Himeji 2022”
本誌掲載ページ: 653-663 p
原稿種別: 論文/英語
電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejjia/12/4/12_22007710/_article/-char/ja/