緩和挙動を用いたポリマー圧電体バイオセンサにおける生体高分子検知特性
緩和挙動を用いたポリマー圧電体バイオセンサにおける生体高分子検知特性
カテゴリ: 論文誌(論文単位)
グループ名: 【E】センサ・マイクロマシン部門
発行日: 2020/02/01
タイトル(英語): Properties of Biopolymers Detection with Piezoelectric Polymer Biosensor in Relaxation Behavior Process
著者名: 武田 真理子(東京都市大学工学部),矢萩 洸貴(東京都市大学工学部),平田 孝道(東京都市大学工学部),黒岩 崇(東京都市大学工学部),中島 千絵(北海道大学人獣共通感染症リサーチセンター バイオリソース部門/北海道大学国際連携研究教育局),鈴木 定彦(北海道大学人獣共通感染症リサーチセンター バイオリソース部門/北海道大学国際連携研究教育局),宗像 文男(東京都市大学工学部)
著者名(英語): Mariko Takeda (Faculty of Engineering, Tokyo City University), Kouki Yahagi (Faculty of Engineering, Tokyo City University), Takamichi Hirata (Faculty of Engineering, Tokyo City University), Takashi Kuroiwa (Faculty of Engineering, Tokyo City University), Chie Nakajima (Division of Bioresources, Hokkaido University Research Center for Zoonosis Control/Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University), Yasuhiko Suzuki (Division of Bioresources, Hokkaido University Research Center for Zoonosis Control/Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University), Fumio Munakata (Faculty of Engineering, Tokyo City University)
キーワード: ポリマー圧電体,緩和挙動,生体高分子,バイオセンサ,ポリフッ化ビニリデン (PVDF) piezoelectric polymer,relaxation behavior,biopolymers,biosensor,poly(vinylidene fluoride) (PVDF)
要約(英語): The complex dielectric constant of a polymer piezoelectric sensor was measured to investigate the properties of biopolymers detection of piezoelectric polymer using relaxation behavior. From the measurement of the complex permittivity, relaxation of the polymer piezoelectric sensor was confirmed. In the properties of the detection of the polymer film, the real part (ε') of the relaxation process linearly shifted to the low frequency with loading the polymer films. This showed the same trend as the result that the frequency shifted to the low frequency with loading mass anticipated from Sauerbrey's equation. In the biopolymer detection, the relaxation was shifted to the low frequency with the fluorescently labeled avidin (the host material) immersion time. With accompanying fluorescently labeled biotin (the guest material) adsorption by host-guest reaction, the relaxation shifted to low frequency. It was considered that the biopolymer detection with the polymer piezoelectric sensor is possible by using relaxation behavior.
本誌: 電気学会論文誌E(センサ・マイクロマシン部門誌) Vol.140 No.2 (2020)
本誌掲載ページ: 43-49 p
原稿種別: 論文/日本語
電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejsmas/140/2/140_43/_article/-char/ja/