商品情報にスキップ
1 1

Spectroelectrochemical Detection of Reduced Water-soluble Tetrazolium Salts Using Disposable Pencil Graphite Electrodes

Spectroelectrochemical Detection of Reduced Water-soluble Tetrazolium Salts Using Disposable Pencil Graphite Electrodes

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【E】センサ・マイクロマシン部門

発行日: 2020/09/01

タイトル(英語): Spectroelectrochemical Detection of Reduced Water-soluble Tetrazolium Salts Using Disposable Pencil Graphite Electrodes

著者名: Toru Yokoyama (Hokkaido University of Science), Daisuke Furuya (Hokkaido University of Science), Toshitsugu Sugawara (Hokkaido University of Science), Takeshi Aikawa (Hokkaido University of Science), Shotaro Watanabe (Hokkaido University of Science), Hisa

著者名(英語): Toru Yokoyama (Hokkaido University of Science), Daisuke Furuya (Hokkaido University of Science), Toshitsugu Sugawara (Hokkaido University of Science), Takeshi Aikawa (Hokkaido University of Science), Shotaro Watanabe (Hokkaido University of Science), Hisae O. Shimizu (Hokkaido University of Science), Masaji Yamashita (Hokkaido University of Science), Tomokazu Indoh (Hokkaido University of Science), Hiroko Miura (Hokkaido University of Science), Kazuyuki Kimura (Hokkaido University of Science)

キーワード: albumin,water-soluble tetrazolium salt,pencil graphite electrode,spectroelectrochemical detection

要約(英語): Microalbuminuria is an important clinical biomarker of diabetes mellitus, chronic kidney disease (CKD), and diabetic KD. However, microalbuminuria detection in urine by immunoturbidimetric method, for early detection and follow-up, is a complicated and expensive procedure compared to the qualitative and semi-quantitative methods, such as the most commonly used dipstick urinalysis. Here, we developed an enzyme- and antibody-free approach using the redox reaction of water-soluble tetrazolium salts (WSTs), which were reduced by albumin and protein and finally produced the colored formazan. Colorimetry was used to spectrometrically detect blue formazan, a reduced WST, and the absorbance was measured at about 600 nm using a microplate reader. The calibration curve for the standard solutions showed that the assay is linear between 0 and 150 mg/L albumin. A simple, rapid, and low-cost fabrication method is proposed here for assembling an electrochemical detection system for formazan using disposable pencil graphite electrodes (PGEs), which are the mechanical pencil leads as working, reference, and counter electrodes. The distinctive voltammetric oxidation peak appeared at +1250 mV vs. PGE by linear sweep voltammetry using a potentiostat. The amperometric oxidation peak current of formazan was applied at +1250 mV vs. PGE by chronoamperometry which required only a few seconds. A correlation was obtained between the oxidation peak maximum current of formazan and concentrations of albumin.

本誌: 電気学会論文誌E(センサ・マイクロマシン部門誌) Vol.140 No.9 (2020) 特集:将来のIoTに向けたセンサ・センシングシステム技術

本誌掲載ページ: 246-250 p

原稿種別: 論文/英語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejsmas/140/9/140_246/_article/-char/ja/

販売タイプ
書籍サイズ
ページ数
詳細を表示する