Radiation power Affected by Electric Field with Changing Wall Radius and Current with Wall-Stabilized Argon Arc

Radiation power Affected by Electric Field with Changing Wall Radius and Current with Wall-Stabilized Argon Arc

通常価格 ¥330 JPY
通常価格 セール価格 ¥330 JPY
セール 売り切れ
税込

カテゴリ: 研究会(論文単位)

論文No: SA16045

グループ名: 【B】電力・エネルギー部門 静止器研究会

発行日: 2016/06/14

タイトル(英語): Radiation power Affected by Electric Field with Changing Wall Radius and Current with Wall-Stabilized Argon Arc

著者名: Yoshifumi Maeda(Tokyo City University),Yuta Shimizu(Tokyo City University),Yuhi Asano(Tokyo City University),Kazuki Sone(Tokyo City University),Shinji Yamamoto(Tokyo City University),Toru Iwao(Tokyo City University)

著者名(英語): Maeda Yoshifumi(Tokyo City University),Shimizu Yuta(Tokyo City University),Asano Yuhi(Tokyo City University),Sone Kazuki(Tokyo City University),Yamamoto Shinji(Tokyo City University),Iwao Toru(Tokyo City University)

キーワード: 放射パワー|電界|器壁半径|電流|器壁安定化アルゴンアーク|電磁熱流体|radiation power|electric field|wall radius|current|wall-stabilized argon arc |electromagnetic thermal fluid

要約(日本語): The brightness is needed in order to illuminate the large area with HID lamp as an emergency large-scale illumination. However, the heat loss increases with increasing the current in order to obtain a high intensity. Therefore, it is required that the radiation power increases at the low input power. Some researchers have researched that the radiation power is in proportion to Nth power of the current, which N parameter is depended on the electric field. However, the calculation model is simple because of the energy balance based on the only heat conduction. Therefore, the arc temperature should be calculated under consideration the radiation loss. It is necessary that the arc temperature distribution is controlled with the wall radius in order to obtain the high radiation power efficiently.In this paper, the radiation power affected by the electric field with changing wall radius and the current with wall-stabilized argon arc is elucidated. The radiation power is calculated by using the electromagnetic thermal fluid (EMTF) simulation and measured with changing the current and the wall radius.

要約(英語): The brightness is needed in order to illuminate the large area with HID lamp as an emergency large-scale illumination. However, the heat loss increases with increasing the current in order to obtain a high intensity. Therefore, it is required that the radiation power increases at the low input power. Some researchers have researched that the radiation power is in proportion to Nth power of the current, which N parameter is depended on the electric field. However, the calculation model is simple because of the energy balance based on the only heat conduction. Therefore, the arc temperature should be calculated under consideration the radiation loss. It is necessary that the arc temperature distribution is controlled with the wall radius in order to obtain the high radiation power efficiently.In this paper, the radiation power affected by the electric field with changing wall radius and the current with wall-stabilized argon arc is elucidated. The radiation power is calculated by using the electromagnetic thermal fluid (EMTF) simulation and measured with changing the current and the wall radius.

原稿種別: 英語