肝臓中を動作可能な磁気マイクロマシンの試作
肝臓中を動作可能な磁気マイクロマシンの試作
カテゴリ: 全国大会
論文No: 2-158
グループ名: 【全国大会】平成16年電気学会全国大会論文集
発行日: 2004/03/17
タイトル(英語): Fabrication of a Magnetic Micromachine which can Move in a Liver
著者名: 相馬宗尚 (東北大学),仙道 雅彦(東北大学),石山 和志(東北大学),荒井 賢一(東北大学)
著者名(英語): Munehisa Soma(Tohoku University),Masahiko Sendoh(Tohoku University),Kazushi Ishiyama(Tohoku University),KenIchi Arai(Tohoku University)
キーワード: 磁気マイクロマシン|回転磁界|らせん構造|肝臓
要約(日本語): A magnetic micromachine capable of moving in a liver was fabricated. It consisted of a stainless steel tip, a permanent magnet, and a spiral shape made with a tungsten wire. The magnet was magnetized in the direction of its diameter. The diameter of the machine was 0.9 mm, small enough for it to be inserted by means of a medical injector. When a rotational magnetic field was applied, the machine rotated and moved in a liver. The micromachine was able to move a distance of 45 mm in bovine liver. It thus has great potential for medical applications.
原稿種別: 日本語
PDFファイルサイズ: 771 Kバイト