Breakdown of Air-polymer Composite Insulation Caused by Partial Discharge
Breakdown of Air-polymer Composite Insulation Caused by Partial Discharge
カテゴリ: 全国大会
論文No: 2-040
グループ名: 【全国大会】平成17年電気学会全国大会論文集
発行日: 2005/03/15
タイトル(英語): Breakdown of Air-polymer Composite Insulation Caused by Partial Discharge
著者名: エカプトラワルディ (豊橋技術科学大学),村上 義信(豊橋技術科学大学),穂積直裕 (豊橋技術科学大学),長尾 雅行(豊橋技術科学大学)
著者名(英語): Waldi Eka Putera (Toyohashi University of Technology),Yoshinobu Murakami(Toyohashi University of Technology),Naohiro Hozumi(Toyohashi University of Technology),Masayuki Nagao(Toyohashi University of Technology)
キーワード: 部分放電
要約(日本語): We have been studying the breakdown characteristic of air-polymer composite insulation under repetitive pulse voltage application using needle-plane electrode system.The purpose of this study is to clarify the effect of dutty of pulses on breakdown. This report the effect of dutty of pulses was investigated.Breakdown phenomenon of air-polymer composite insulation system under repetitive pulse voltage was studied. Increasing duty of pulse reduced the number of pulses to breakdown.
原稿種別: 日本語
PDFファイルサイズ: 978 Kバイト