Breakdown of Air-polymer Composite Insulation due to Partial Discharge in Air
Breakdown of Air-polymer Composite Insulation due to Partial Discharge in Air
カテゴリ: 全国大会
論文No: 2-027
グループ名: 【全国大会】平成18年電気学会全国大会論文集
発行日: 2006/03/15
タイトル(英語): Breakdown of Air-polymer Composite Insulation due to Partial Discharge in Air
著者名: エカプトラ ワルディ(豊橋技術科学大学),村上 義信(豊橋技術科学大学),穂積直裕 (豊橋技術科学大学),長尾 雅行(豊橋技術科学大学)
著者名(英語): putra waldi eka (toyohashi university of technology),yoshinobu murakami(toyohashi university of technology),naohiro hozumi(toyohashi university of technology),masayuki nagao(toyohashi university of technology)
キーワード: 部分放電|デューティーパルス
要約(日本語): We have been studying the breakdown characteristics of air-polymer composite insulation under repetitive pulse voltage using the needle plane system. We found that it changes with the duty ratio. In dynamic partial discharge in air gap, a discharge would be influenced by the back discharge. The change in the distribution of the surface charge that remain after the last discharge may influence the next discharge in the air gap. In this report, the investigation on the above effect is described.
原稿種別: 日本語
PDFファイルサイズ: 1,342 Kバイト