電気光学効果とCT法を利用した電界分布測定法の精度向上手法
電気光学効果とCT法を利用した電界分布測定法の精度向上手法
カテゴリ: 論文誌(論文単位)
グループ名: 【A】基礎・材料・共通部門
発行日: 2011/06/01
タイトル(英語): Improvement of the Accuracy for the Measurement of Electric Field Distributions using Kerr Electrooptic Effect and Computed Tomography Mehod
著者名: 升市 直哉(愛媛大学),藤井 雅治(愛媛大学),井堀 春生(愛媛大学)
著者名(英語): Naoya Masuichi (Ehime University), Masaharu Fujii (Ehime University), Haruo Ihori (Ehime University)
キーワード: CT法,逐次近似,電界分布,画像再構成 computed tomography,iterative reconstruction,electric field,image reconstruction
要約(英語): Computed tomography (CT) method has been used for industrial application as well as it has been mainly developed in a medical field. We have investigated the measurement of nonuniform electric field vector distributions in liquid dielectrics using an original method based on electrooptic Kerr effect and CT method. In applying CT method to the reconstruction of the electric field, a principle of CT method has been faithfully observed, which has been one of cause of the error. Specifically, region passing through of the light for measurements was not equal to the reconstructed region and the electric field was reconstructed without consideration of the value of cells outside of the region for reconstruction. So, to solve these problems, we suggested the improved algorithm for reconstruction using the concepts which we called “actual region projection data” and “extension of region for reconstruction”. By a simulation and an experiment, the usefulness of the improved method was studied.
本誌: 電気学会論文誌A(基礎・材料・共通部門誌) Vol.131 No.6 (2011) 特集:電気電子絶縁材料システムシンポジウム
本誌掲載ページ: 472-477 p
原稿種別: 論文/日本語
電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejfms/131/6/131_6_472/_article/-char/ja/