核融合実験施設におけるバースト的高周波漏洩電界の測定及び心臓ペースメーカーへの電磁干渉評価

核融合実験施設におけるバースト的高周波漏洩電界の測定及び心臓ペースメーカーへの電磁干渉評価

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【A】基礎・材料・共通部門

発行日: 2012/05/01

タイトル(英語): Measurement of Leaked High-Frequency Burst Electric Field and EMI Evaluation for Cardiac Pacemaker in Fusion Facility

著者名: 山中 幸雄((独) 情報通信研究機構),王 建青(名古屋工業大学),藤原 修(名古屋工業大学),宇田 達彦(核融合科学研究所)

著者名(英語): Yukio Yamanaka (National Institute of Information and Communications Technology), Jianqing Wang (Nagoya Institute of Technology), Osamu Fujiwara (Nagoya Institute of Technology), Tatsuhiko Uda (National Institute for Fusion Science)

キーワード: 核融合,漏洩電磁界,統計分布,電磁干渉  fusion experimental facility,leaked electromagnetic field,statistical distribution,electromagnetic interference

要約(英語): In this study, we measured the time variation of burst electric fields leaked from a heating device in the ion cyclotron range of high-frequency in an experimental fusion facility, and analyzed their statistical characteristics such as the amplitude probability distribution (APD) and crossing rate distribution (CRD). As a result, we found that the variation of the leaked electric field level is very irregular, far from the normal distribution. Moreover, the leaked electric field variation with time may reach 400 times in one second to cross its mode value. Although so, the maximum electric field intensity itself is much smaller than the ICNIRP safety guideline. In addition, we also evaluated the possibility of electromagnetic interference to an implanted cardiac pacemaker in the measured electromagnetic environment. We found that even in the worst case the interference voltage induced in the output of the pacemaker sensing circuit does still not exceed the threshold for a malfunction.

本誌: 電気学会論文誌A(基礎・材料・共通部門誌) Vol.132 No.5 (2012) 特集:静電気放電(ESD)のEMC技術

本誌掲載ページ: 356-361 p

原稿種別: 論文/日本語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejfms/132/5/132_5_356/_article/-char/ja/