商品情報にスキップ
1 1

The Influence of Polarity Reversal on Two-layered EPR and LDPE Simulating DC Cable Joints

The Influence of Polarity Reversal on Two-layered EPR and LDPE Simulating DC Cable Joints

通常価格 ¥770 JPY
通常価格 セール価格 ¥770 JPY
セール 売り切れ
税込

カテゴリ: 論文誌(論文単位)

グループ名: 【A】基礎・材料・共通部門

発行日: 2019/02/01

タイトル(英語): The Influence of Polarity Reversal on Two-layered EPR and LDPE Simulating DC Cable Joints

著者名: Tsuyoshi Tohmine (Measurement and Electric Machine Control Lab, Tokyo City University), Kumiko Iguchi (Measurement and Electric Machine Control Lab, Tokyo City University), Keita Sonoda (Measurement and Electric Machine Control Lab, Tokyo City University)

著者名(英語): Tsuyoshi Tohmine (Measurement and Electric Machine Control Lab, Tokyo City University), Kumiko Iguchi (Measurement and Electric Machine Control Lab, Tokyo City University), Keita Sonoda (Measurement and Electric Machine Control Lab, Tokyo City University), Hiroaki Miyake (Measurement and Electric Machine Control Lab, Tokyo City University), Yasuhiro Tanaka (Measurement and Electric Machine Control Lab, Tokyo City University), Yoshinao Murata (Sumitomo Electric Industries, Ltd.), Yukito Ida (Sumitomo Electric Industries, Ltd.), Yoshiyuki Inoue (Sumitomo Electric Industries, Ltd.)

キーワード: space charge,pulsed electro-acoustic method,cable accessories,polarity reversal

要約(英語): The consideration of space charge accumulation characteristics in DC cable systems are important. However, there have not been many reports on the space charge accumulation characteristics at the joints, although there have been many reports at the cables itself. Therefore, space charge accumulation characteristics at the joints must be put into account, since interface charge accumulation caused by the difference in permittivity, conductivity, etc. is likely to occur, since two different types of insulating materials are being used. It is also likely that a polarity reversal of the applied voltage to the insulating material causes an unexpected accident at the joints in the cable system, while in some power transmission systems, the polarity reversal is an inevitable procedure. Therefore, in this paper, we investigated the influence of polarity reversal upon space charge distribution and electric field distribution in two-layered samples composed of different materials, to identify issues in cable joints under DC voltage.

本誌: 電気学会論文誌A(基礎・材料・共通部門誌) Vol.139 No.2 (2019) 特集:2017 International Symposium on Electrical Insulating Materials

本誌掲載ページ: 78-84 p

原稿種別: 論文/英語

電子版へのリンク: https://www.jstage.jst.go.jp/article/ieejfms/139/2/139_78/_article/-char/ja/