太陽電池モジュールの互換性に関する検討―PCSのMPPT制御方式を考慮した逆電圧発生シミュレーション―
太陽電池モジュールの互換性に関する検討―PCSのMPPT制御方式を考慮した逆電圧発生シミュレーション―
カテゴリ: 論文誌(論文単位)
グループ名: 【B】電力・エネルギー部門
発行日: 2014/08/01
タイトル(英語): Study on Interrelationship of PV Modules―Simulation of Reverse Voltage Taking Account of MPPT Control Method in PCS―
著者名: 堀江 康介(同志社大学理工学部),高橋 康人(同志社大学理工学部),藤原 耕二(同志社大学理工学部),石原 好之(同志社大学理工学部),高橋 克弥(日本大学理工学部),西川 省吾(日本大学理工学部),加藤 宏((一財)電気安全環境研究所)
著者名(英語): Kosuke Horie (Faculty of Science and Engineering, Doshisha University), Yasuhito Takahashi (Faculty of Science and Engineering, Doshisha University), Koji Fujiwara (Faculty of Science and Engineering, Doshisha University), Yoshiyuki Ishihara (Faculty of Science and Engineering, Doshisha University), Katsuya Takahashi (Faculty of Science and Engineering, Nihon University), Shogo Nishikawa (Faculty of Science and Engineering, Nihon University), Hiroshi Kato (Japan Electrical Safety & Environment Technology Laboratories)
キーワード: 太陽電池モジュール,互換性,逆電圧,最大出力点追従制御,シミュレーション photovoltaic (PV) module,interrelationship,reverse voltage,maximum power point tracking (MPPT),simulation
要約(英語): This paper investigates the influence of MPPT control method in the PCS on the occurrence of reverse voltage in PV modules. When the power of modules in part of a PV array declines, a situation arises in which those modules must be replaced with modules of different rated value. In such a case, the difference in the characteristics of existing modules and replacement modules may cause the occurrence of reverse voltage by MPPT control of the PCS in the replacement modules, which may cause heat and ignition. Although protection devices are connected to protect the modules from the occurrence of reverse voltage, they may not work. Therefore, it is indispensable to clarify the range of safe combinations of modules of different rated value. First, an MPPT control algorithm of three kinds of PCSs is implemented. To validate the developed control algorithm the simulated operating voltage is compared with measured one. Second, in order to clarify the conditions under which reverse voltage is likely to occur, the influence of the MPPT operation, open circuit voltage and short circuit current of PV modules and the pattern of connection of existing and replacement modules in a PV array on the occurrence of reverse voltage is investigated.
本誌: 電気学会論文誌B(電力・エネルギー部門誌) Vol.134 No.8 (2014) 特集:最近の電線・ケーブル技術
本誌掲載ページ: 673-681 p